A pipe dripping on the outside wall, a funnel in the airing cupboard that's suddenly wet, hot water that's gone cold or gone weak, a bang when the taps shut off. An unvented cylinder is a mains-pressure tank with a set of safety valves around it, and every one of those symptoms is one of the valves, the vessel or the heaters telling you something specific. This guide explains what each fault means in plain English, what's safe to check yourself, and when to stop and call someone qualified. Written by DT Plumbing and Building in Crawley, who see these cylinders every week across Sussex and Surrey.
A traditional vented cylinder is filled from a cold water tank in the loft, so the hot water comes out at whatever pressure gravity gives it. An unvented cylinder is filled straight from the mains. There's no tank in the loft, the hot water upstairs comes out as hard as the cold, and the showers are the better for it. The price of that is a tank holding water at mains pressure that expands as it heats, so the cylinder is surrounded by equipment whose only job is to keep that safe: a group of valves on the cold inlet that strains the water, reduces the pressure and stops it flowing backwards; an expansion vessel (or, on some cylinders, an air pocket inside the tank) that gives the heated water somewhere to go; an expansion relief valve and a temperature and pressure relief valve that open if the pressure or the temperature climbs too far; and a tundish, the small open funnel in the pipework, which carries anything those valves let out down a discharge pipe to a safe spot outside. Because of all that, the Building Regulations (Part G3) say an unvented cylinder must be installed and serviced by someone holding the unvented qualification, and the cylinder carries a label saying so.
The cylinder is heated one of two ways. A direct cylinder has one or two electric immersion heaters and nothing else. An indirect cylinder has a coil inside fed by the boiler or a heat pump, usually with an immersion heater as a back-up. That matters for what follows, because on an indirect cylinder a hot water fault can sit on the boiler side, which is a Gas Safe registered engineer's job, and we'll say so when it does. New-build estates around Horley, Pease Pottage and the newer parts of Crawley are almost all unvented, and plenty of older houses have gone the same way when the bathroom was done.
This is the one that brings most people to this page. The tundish is designed to be dry. The moment it's wet, one of the two relief valves has opened, and when it opened tells you why. A drip that starts while the cylinder is heating and stops once the water is hot means the expansion vessel has lost its air charge: the heated water has nowhere to expand into, the pressure rises, and the expansion relief valve on the inlet group lifts to let a little out. Recharging the vessel, or part-draining a cylinder that uses an internal air pocket instead, puts that right, and if the vessel's diaphragm has split it gets replaced. A drip that never stops, heating or not, usually means the valve seat itself has scaled up and won't close, or the pressure reducing valve on the inlet has failed and is letting full mains pressure through to a valve set to open just above the working pressure. Either way it's a part, not a mystery. Hot or steaming water from the tundish is different and is the only one of these that's urgent: the temperature and pressure relief valve has opened because the cylinder is overheating, which means a thermostat or a cut-out has failed. Switch the immersion heater off at its isolator, switch the hot water off at the programmer, and ring. Whatever the cause, never cap, block or re-route the discharge pipe to stop the drip; it is the last line of defence and it has to run to open air where it can be seen.
On a direct cylinder the hot water comes from the immersion heaters, and those are wear parts, especially in our hard water, where limescale coats the element until it burns out. Each immersion on an unvented cylinder also has a thermal cut-out with a manual reset button under its cap, and a cut-out that has tripped looks exactly like a failed element from the tap end. One reset, with the power off, is reasonable; a cut-out that trips again means the immersion thermostat is sticking on and letting the water overheat, and the thermostat needs replacing before the cut-out is asked to save the day a third time. Many direct cylinders have two immersions, a main one low down and a boost one near the top, so a cylinder that gives you a few minutes of hot water and then runs cold has often lost the lower element and is running on the boost. On an indirect cylinder the same short chain as any heating system has to agree before the coil gets any heat: programmer calling for hot water, cylinder thermostat saying it's cold, motorised valve opening. We check those in order. If the chain is fine and the boiler itself has locked out or lost pressure, that part is a Gas Safe registered engineer's job, and we'll point you to one. Everything on the water side, from the cylinder and its controls out to the taps, is covered on our no hot water page.
The test takes ten seconds: run the cold at the kitchen tap, then the hot. If the cold is as strong as ever and the hot has gone feeble at every tap, the restriction is at the cylinder inlet. The strainer in the inlet group collects scale and grit from the mains and silts up over the years, the pressure reducing valve can fail towards closed, and an isolation valve that was half-shut after some earlier work is a surprisingly common find. A cleaned strainer or a new inlet group brings the pressure straight back. If the cold is weak too, the problem is upstream, in the stopcock, the supply pipe or the water company's main, and the cylinder is innocent. If only one tap or the shower is weak, it's that outlet, and our shower repair and leaking tap pages cover those.
A single bang when a tap or an appliance shuts off is water hammer, and on an unvented system it usually means the expansion vessel is flat (the same fault as the heating-only drip, which it's often found alongside) or the pressure reducing valve is letting the pressure creep up when nothing is running. A hum or a whistle that changes as a tap is opened tends to be the pressure reducing valve itself, worn and chattering. A rumble or a kettle-like crackle while the cylinder is heating is limescale on the immersion element or, on an indirect cylinder, in the coil, and it means the element is working harder and will fail sooner. None of these are dangerous today; all of them are a cylinder asking for its annual service.
Stored hot water is meant to sit at around sixty degrees, hot enough to keep bacteria out of the cylinder, and most systems then blend it down at the outlets so nobody gets scalded. Water that's suddenly hotter than it used to be, or that comes with the tundish running warm, points to the immersion thermostat or the cylinder thermostat failing and letting the heater run on. Water that's never properly hot, on a cylinder that used to manage it, is usually a thermostat set low after some other work, a scaled immersion that can't keep up, or on an indirect cylinder a coil that's furred. We set the thermostats where they should be and test the heaters rather than guess, because turning the stat up to cure a scaled element just moves the problem to the cut-out.
Weeping at the immersion heater boss is the gasket, and it's a straightforward change. A damp patch under the inlet group or the relief valves is a compression joint or a valve that's been dripping back along the pipe, and gets re-made or replaced. A cylinder that's wet on its shell, or that has a stain spreading from under the insulation jacket, has usually failed from the inside, and no repair fixes that; it's a replacement, which on an unvented cylinder means the inlet group, expansion vessel, relief valves and discharge pipe all being checked or renewed at the same time so the new tank is protected properly. Before that gets quoted, check the paperwork: most unvented cylinders are sold with a long warranty on the tank, and some of the newer homes we visit around Horley and Pease Pottage still have cylinders inside it. If a serviced cylinder has failed within its warranty, we'll say so and point you back to the maker rather than sell you a new one. Water under the cylinder with no obvious source is one for a careful look rather than a guess, and our leak detection page explains how that's done.
Every unvented cylinder is meant to be checked once a year, and the makers usually make their warranty depend on it. It isn't a strip-down. The relief valves are lifted to prove they open and reseat, the expansion vessel's charge is measured and topped up, the inlet strainer is cleaned, the thermostats and cut-outs are checked, the immersion heaters are tested, and the discharge pipe is confirmed clear and running to the right place. In a hard water area like ours, that strainer and those valve seats are what fail first, and nearly every drip described on this page is a service that never happened. If your cylinder has never been looked at since the day it went in, that's the place to start.
Safe, and genuinely useful to us on the phone: look at the tundish and note whether it's wet, and whether the drip comes while the water's heating or all the time; feel whether the water in it is cold or hot; read the pressure gauge if there is one; check the immersion heater is switched on at its isolator and the fuse hasn't gone; check the cold water is strong at the kitchen tap; and take photos of the cylinder label, the valves on the inlet, the vessel and anything that's dripping. That's enough for a free written quote on most repairs, often the same day.
Not safe, and not yours to do: removing an immersion heater cap with the power on; adjusting, lifting or replacing either relief valve; recharging or changing the expansion vessel; capping, shortening or re-routing the discharge pipe; or replacing the inlet group or the cylinder. Those are the parts that stop a mains-pressure tank becoming dangerous, the regulations put them in the hands of someone holding the unvented qualification, and that's a job we have covered. A cylinder that's been worked on by someone without it is also outside its warranty from that day on.
Three steps. No surprises.
The cylinder label, the valves on the inlet, the vessel, the tundish and whatever's dripping, plus when it does it. For a vessel recharge, a relief valve, a thermostat or an immersion heater, that's usually enough for a free written quote from your photos the same day. For a replacement, or a fault that's not obvious, we come and look properly first.
Unvented cylinders need someone qualified under G3 to work on the safety equipment, and we have that covered. The valves, vessel, inlet group, heaters and thermostats are tested rather than swapped on a hunch, so you pay for the part that's actually failed. If the fault turns out to be the boiler, we'll say so and point you to a Gas Safe registered engineer for that part.
The cylinder is brought up to temperature with a hand on the tundish before we call it done, the vessel charge and the valve test are noted for your warranty file, and you get a clear price before we start and an itemised VAT receipt by email. Pay by card on the spot with our Stripe card reader, by bank transfer (BACS), or cash.
How a quote is put together, including what's priced from photos and what isn't, is on how we price. Everything else we do is on the services page.
If the pipe comes out of the wall near the airing cupboard or wherever your hot water cylinder lives, it is almost certainly the discharge pipe from an unvented cylinder. Inside, that pipe starts at a small open funnel called the tundish, and anything the cylinder's safety valves let out runs through it to the outside. A drip that appears while the water is heating and stops once it is hot nearly always means the expansion vessel has lost its air charge, so the water has nowhere to expand into and the pressure lifts the relief valve. A constant drip, hot or cold, usually means a valve seat has scaled up or the pressure reducing valve on the inlet has failed. Hot or steaming water from that pipe means the cylinder is overheating, which is the one to switch off and ring about straight away.
A cold drip during heating is the safety system doing its job, and you can carry on using the water while you arrange a visit. It is not something to live with, though: the valve that is dripping is being asked to do the expansion vessel's work, it wears, and a valve that has been weeping for months will not seat properly when it is genuinely needed. If the water in the tundish is hot or steamy, switch the immersion heater off at the wall, turn the hot water off at the programmer if the cylinder is heated by the boiler, and call us. Never block, cap or disconnect the discharge pipe to stop the drip.
The immersion heater on an unvented cylinder has a thermal cut-out with a small manual reset button, usually under the plastic cap on top of the element, and it trips if the water gets too hot. It is designed to be reset, but the cap sits over live electrical connections, so only touch it with the power switched off at the isolator, and only once. A cut-out that trips a second time is telling you something has failed, most often the immersion thermostat sticking on, and pressing the button again just turns a safety device into a fault you are ignoring. Switch it off and have it looked at.
Look in the loft first. A vented cylinder is fed from a cold water tank up there; an unvented one is fed straight from the mains and there is no tank. Beside an unvented cylinder you will find a group of brass valves on the cold inlet, a round expansion vessel or a cylinder designed with an air pocket inside, a small open funnel in the pipework (the tundish) and, on most, a pressure gauge. The hot water upstairs comes out at the same strong pressure as the cold. There will also be a label on the cylinder saying it must be installed and serviced by someone qualified under Building Regulations G3.
Yes, and most cylinder makers make their long warranties conditional on it. An annual service is a check rather than a strip-down: the relief valves are lifted to prove they open and reseat, the expansion vessel charge is measured and topped up, the strainer in the inlet group is cleaned of scale and grit, the thermostats and the discharge pipe are checked, and the immersion heaters are tested. In a hard water area like ours it is the strainer and the valve seats that go first, and a short annual visit is a great deal cheaper than a cylinder that is out of warranty because nobody ever looked at it.
For most repairs, yes. A photo of the cylinder with its label, the group of valves on the inlet, the expansion vessel, the tundish and whatever is dripping is usually enough for a free written quote the same day, with the honest caveat that if it looks different on the day we tell you before any work starts. For a cylinder replacement, or where the fault is not obvious from the photos, we come and look properly first, because the pipework, the discharge route and the condition of the cylinder decide the job.
Yes. Unvented cylinders need someone qualified to work on them under Building Regulations G3, and we have that covered: the relief valves, expansion vessel, inlet group, immersion heaters and thermostats, the tundish and discharge pipe, annual servicing and full replacement. The same arrangement covers the rest of your hot water system. If your cylinder is heated by a gas boiler and the boiler itself is at fault, that part belongs to a Gas Safe registered engineer and we will point you to one (gassaferegister.co.uk), the right trade on every part of the job.
Call or WhatsApp with a photo of the cylinder and its valves, and we'll tell you honestly what it is and what it involves.